Startup and Main Windows : MegaRAID Storage Manager Main Menu Window : Dashboard/Physical View/Logical View

Dashboard/Physical View/Logical View

The left panel of the MegaRAID Storage Manager window displays the Dashboard view, the Physical view, or the Logical view of the system and the attached devices, depending on which tab is selected.

The Dashboard view displays an overview of the system and covers the following features, as shown in the following figure:

n

Properties of the virtual drives and the physical drives

n

Total capacity, configured capacity, and unconfigured capacity

n

Background operations in progress

n

MegaRAID Storage Manager software features and their status (enabled or disabled)

n

Actions you can perform, such as creating a virtual drive and updating the firmware

n

Links to Online Help

Figure 9 Dashboard View

 

* 

NOTE If the controller supports High Availability clustering, the HA Peer Controller Status field shows in the above dialog with one of the following values: Active (both the servers in the cluster are running), Inactive (only one server is running), Incompatible (there is incompatibility between the servers).

 

The Physical view displays the hierarchy of physical devices in the system. At the top of the hierarchy is the system itself, followed by the controller and the backplane. One or more controllers are installed in the system. The controller label identifies the MegaRAID controller, such as the MegaRAID SAS 9260-8i controller, so that you can easily differentiate between multiple controllers. Each controller has one or more ports. Drives and other devices are attached to the ports. The properties for each item appear in the right panel of the screen.

Figure 10 Physical View

 

If the controller supports High Availability clustering, you will see an additional parent node, Server Domain, on the device tree in the Physical tab, as shown below.

Figure 11 Physical View for High Availability Clustering

The Server Domain is the domain ID of the cluster and shows the two servers that belong to it as child nodes. Information (such as controller name, enclosures, physical drives) pertaining to the logged in server in the cluster is shown in the Physical tab. For the peer server, no details are shown; the Physical tab just detects that a peer server exists and a controller is attached to it. Right click on Server Domain to view the properties of the cluster. A view only properties dialog shows with two fields; Domain ID and No. of Servers Tagged.

The Logical view shows the hierarchy of controllers, virtual drives, the drives, and the drive groups that make up the virtual drives, as shown in the following figure. The properties for these components appear in the right panel.

Figure 12 Logical View

If the controller supports High Availability clustering, you will see an additional parent node, Server Domain, on the device tree in the Logical tab, as shown below.

Figure 13 Logical View for High Availability Clustering

The Server Domain is the domain ID of the cluster and shows the two servers that belong to it as child nodes. Information (such as controller name, drive groups, virtual drives) pertaining to the logged in server in the cluster is shown. For the peer server, the Logical tab detects that a peer server exists and a controller is attached to it and shows only the virtual drives created by the peer server. Right click on Server Domain to view the properties of the cluster. A view only properties dialog shows with two fields; Domain ID and No. of Servers Tagged.